Beijing Zero Time...

Electrochemical sensors measuring principle

Detection of sulfur dioxide gas

Measuring range 0-20ppm (can be customized 0-1000ppm)

Detection accuracy of ?5% F.S

Alarm set points can be set according to according to user requirements

Alarm Type Sound Alarm: Buzzer 80dB at 30cm

Power Supply 3.6V rechargeable battery

Temperature -10 ℃ ~ 40 ℃

Relative humidity 0-90% R.H

Size of 138 ?53 ?33mm

Shell Engineering Plastics

The form of intrinsic safety explosion-proof

Explosion-proof mark Exia II CT4

Standard high-grade aluminum case packing equipment; accessories: screwdriver, guide trachea, manual

Sensor life expectancy of two years

Model CGD-I-ASO2